IFHT - Centrifugal Induction Fan

  Features

  • The Centrifugal Induction fan, size 100N thrust, is designed to induce air movement in enclosed car parking and for emergency smoke operation at F400 or F300.

  Construction

  • The galvanised steel backward curved centrifugal impeller is balanced in accordance with ISO 1940-1, G6.3. 
  • The fan duct is made from galvanised steel and an inlet steel guard is supplied.
  • The external electrical terminal box makes connection easier.

  Motors    Impellers

  • Motors are totally enclosed airstream cooled, protected to IP55 with each motor matched to the aerodynamic performance of the impeller.
  • Motors are Class H insulation for normal continuous duty at maximum ambient 40°C.
  • Electricity supply - 400/50 HzV, three-phase.
  • Two speed 4/8 pole Dalhander winding.

Testing

  • Complete fan assembly independently tested and approved in accordance with EN12101-3 at F400 or F300.

  Dimensions

  Technical Data

  Fan     Nom Max. Start Sound Sound  
  Speed Thrust Airflow Power abs Current level Pressure  
Model IFHT r.p.m. N m3/hr kW Cur (A) (A) (Lwa) dB(A)@3m Kg
100N-C-4/8 1420/710 95/24 8900/4450 2.3/0.37 5.4/109 30/7.5 95/79 78/2 120

  Auto Cad

  PDF

Download AUTO CAD file